From: route@monster.com
Sent: Saturday, April 16, 2016 2:04 PM
To: hg@apeironinc.com
Subject: Please review this candidate for: NSN Construction Manager
This resume has been forwarded to
you at the request of Monster User xapeix03
|
|||||||
|
|||||||
|
|
|
||||||
|
||||||
|
Travis M. Sharpe 5050 Old Walland Hwy. Walland, TN 37886 (682)888-6660 sharpey607@gmail.com CAREER OBJECTIVE: A position as a Area manager or within the Engineering
field. EDUCATION: ITT-Tech - Associate of Electrical Engineering Technology SKILLS: ·
15 years experience in Central office
zones 1-4,Outside plant, Commercial & Residential post & pre construction
,Cellular sites, AC & DC Power -Tyco, Marconi, Lorain, Emerson, PECO II,
Valere Power & Adtran systems. ·
Labeling software from Brady, P-
touch, Panduit on a daily basis. ·
Share point, Excel, Word, power
point, outlook ·
Excellent Knowledge of customer’s
standards (Telecordia,Verizon, At&t, Qwest(Century Link) ·
Tellabs 5500-1024-2048-3072, 6500,
532l, 256e, 7200, 8860, 3100, Fujitsu Flashwave 4100,4500, Nortel DMS 100,500
switches, Succession, Cinea, Geomax, Spirent, Dantel , D –max, Motorola,
Alcatel, Cisco CRS 8/16, Nexus 7K & 9k, Brocade, Lucent, Nokia, Red Back,
Westell, Hyper-edge, Juniper MX-960 systems & Info Blox, F5, Cisco server
& router systems. CERTIFICATIONS: ·
AC/DC Electrical Theory and
Application ·
Power Plants and Systems ·
Central Office Bonding &
Grounding Policy ·
Battery Technologies for
Telecommunications Equipment Locations ·
Performing DC "Hot" Cutover
Procedures (An examination of the Detailed Method of Procedure) ·
OSHA ·
ATS Bar Code & Scanning ·
LCC & BNC ·
Hilti & 3M Fire Stop Systems ·
Hilti Powder Actuated Tools ·
Dantel Alarm Systems ·
Fibercom Fiber splicing ·
Central Office Equipment Engineering
Drawing Symbols ·
Central Office Installation
Workmanship Assessment Competency Aptitude ·
At&t - Premise
Technician ·
At&t – Ask yourself ·
At&t – supplier awareness ·
At&t – Quality Installations ·
At&t – Best method ·
At&t – Fiber cleaning ·
At&t – Fiber handling WORK HISTORY: GDT 1/12-Present Field Manager & Field Engineer (level 4) Engineered and Installed Cisco CRS VE & PE, Nexus 7K
& 9K’s.Preformed upgrades on 8 slot CRS’s and preformed live traffic cut
over’s & Installed Brocade equipment, performed migrations of Juniper and
Cisco equipment. Ran power from batteries to BDFB’s, Ran, stitched,
terminated, torque & marked cables power from relay rack’s to BDFB’s,
tested and fused all. Worked with Customer and Supplier on a Daily basis,
basic Installation, Following and writing of Spec’s & MOP’s, Running
& forming of DS1, DS3, CAT5 & Fiber optic cables, connection of All
Cables, fiber splicing, preformed (T-Berd, MT 5000, Voltage, Amp) test on all
cables & System turn up Telamon Inc. 1/10-1/11 Lead Foreman & Field Engineer (Level 4) Engineered and ordered material for equipment, Ran,
stitched, terminated torque & marked cables to panels and return bar. Ran
power from batteries to BDFB’s, Ran, stitched, terminated, torque &
marked cables power from relay rack’s to BDFB’s, tested and fused all.
Completed At&t electronic folders, worked with software such as share
point, e-time, tee-fit word excel, citrix and outlook. Received work orders
from AT&T, performed site surveys, ordered materials, installed jobs,
test and turn up, performed quality audits on all AT&T Riser customer
prem. sites Worked with Customer and Supplier on a Daily basis, basic
Installation, Following and writing of Spec’s & MOP’s, Running &
forming of DS1, DS3, CAT5 & Fiber optic cables, connection of All Cables,
fiber splicing, preformed (T-Berd, MT 5000, Voltage, Amp) test on all cables
& System turn up of Cisco switches and routers TechForce 1/09- 1/10 Area Supervisor (Level 4) Ran, stitched, terminated, torque & marked cables
power from battery’s to BDFB’s. Ran, stitched & terminated power from
relay rack’s to BDFB’s, tested and fused all. Received work orders from
AT&T, performed site surveys, ordered materials, installed jobs, test and
turn up, performed quality audits on all AT&T Riser customer
prems. Worked with Customer and Supplier on a Daily basis, basic
Installation Following Spec’s & MOP’s, Running & forming of DS1, DS3,
CAT5 & Fiber optic cables, connection of All Cables, fiber splicing,
preformed (T-Berd, MT 5000, Voltage, Amp) test on all cables & System
turn up. Hung cable support brackets, Ran Voice, Data & Speaker Cable
from rooms to IDF & MDF's Formed and Terminated Jacks & Patch
Panels. Alamon Inc. 11/07- 1/09 Lead Installer (Level 4) Worked
side by side with Qwest on Installation, Removal, and Trouble shooting of
Tellabs, Nortel, Alcatel, Fujitsu, Cisco switches and routers along with
Fiber to the node projects. All work consist of basic Installation following
Spec’s & MOP’s, Running & forming of DS1, DS3, CAT5, Power &
Fiber optic cables, connection of All Cables, Labeling & Testing of
all cables and equipment. Engineered and ordered material for equipment,
Ran, stitched, terminated torque & marked cables to panels and return
bar. Ran power from batteries to BDFB’s, Ran, stitched, terminated, torque
& marked cables power from relay rack’s to BDFB’s, tested and fused all. Pride Communications 8/06-11/07
(contract ended) Lead Installer (Level
4) Fiber
splicing, Test and turn up of Nortel SPME, Tellabs HD 5500 Motorola Fiber to
the node projects and Ditech shelf’s Worked with Customer and Supplier
on a Daily basis, basic Installation Following Spec’s & MOP’s,
Running & forming of DS1, DS3, CAT5, Power & Fiber optic cables,
connection of All Cables.
PIVOTEL, LLC 7/99-08/06
Area
Supervisor (Level 4)
Worked
with Customer and Supplier on a Daily basis, basic Installation Following
Spec’s & MOP’s, Running & forming of DS1, DS3, CAT5 & Fiber optic
cables, connection of All Cables, fiber splicing, preformed (T-Berd, MT 5000,
Voltage, Amp) test on all cables & System turn up & trouble shooting
Management of Installation crews on sites, prepared all MOP’S (Power,
Critical, General, Detailed) for all Customers, prepared all paperwork for
Customer, Supplier and Vendor’s during and at the end of all jobs, performed
Quality Audits on all jobs, preformed tests on various Tellabs equipment,
Fujitsu, Spirent and Dantel equipment. Engineered and ordered material for
equipment, performed migrations of Cisco and juniper equipment. Ran,
stitched, terminated torque & marked cables to panels and return bar. Ran
power from batteries to BDFB’s, Ran, stitched, terminated, torque &
marked cables power from relay rack’s to BDFB’s, tested and fused all.
REFERENCES: Doug Curto –
AT & T LNS/Area Manager – 602-617-3260 Frank Figueroa- Qwest/Q.T.I (Century Link) Field Supervisor –
520-292-7021 Len Thumma-
Qwest/Q.T.I (Century Link) – 520-861-9377 |
|
|
||||||||
|
|
||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||
|
|